Note:

The star energy label, issued by the Ministry of Industry and Trade of Vietnam, shows the consumers, level of air conditioner's energy efficiency.

FTXZ Series (Urusara 7)

Urusara 7 brings you to a new level of comfort by offering a unique, total comfort experience for any lifestyle. Latest advances in Japanese air conditioning technology is now at your fingertips.

  • Energy saving
  • Next-generation refrigerant
  • Humidity control
  • Airflow control
  • Designed in Japan
  • Air purification
  • Automatic filter cleaning
Download Catalogue
Where to buyWhere to buy Compare ProductsCompare Products

Features

Circulation Airflow

This function uses the Coanda effect to rapidly achieve the set temperature. The double air intakes and cross flow fan increase airflow to circulate air around a room.

Breeze Airflow

This function recreates the natural rhythm of a gentle breeze. With this airflow pattern, even people who are sensitive to drafts feel comfortable when air is directed towards them.

Auto off operation

If no movement in a room > Temperature can be set to 2°C warmer.
If no movement in 1 to 3 hours > Stop operation. > Temperature can be set to 2°C warmer.

Power-Airflow Flap

The Power-Airflow Flap regulates the outlet aperture to an optimum shape.

Wide-Angle Louvers

The Wide-Angle Louvers provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room. 

3D airflow

3-D airflow combines vertical and horizontal auto-swing to circulate air to every part of a room for uniform cooling of even large spaces. This function is available for models FTKV50/60.

Vertical Auto-Swing (up and down)

This function automatically moves the flaps up and down to distribute air across a room.

Horizontal Auto-Swing (left and right)

Horizontal Auto-Swing automatically moves the louvers to the left and right to cover a room with cool or warm air.

3 Area Intelligent Eye (Focus)

The eye detects and adjusts the airflow directly to the person.

3 area Intelligence Eye (Comfort)

The eye detects an area and avoid blowing air directly onto the person.

Sarara Dry Operation

This dehumidifying function stabilises the room temperature and prevents overcooling, even for people who are particularly sensitive to cold.

Dry Cooling Operation

This combined dehumidifying and cooling operation dehumidifiers by cooling at a low airflow rate, resulting in a lower room temperature.

Hot-Start Function

After defrosting or when staring heating operation, air is pre-heated before discharge to prevent uncomfortable cold draft.

Automatic fan speed

The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature.

Fan only

The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature.

Automatic operation

This function automatically selects cooling or heating operation mode based on the room temperature at start-up.

Indoor Unit Quiet Operation

Indoor unit operating sound pressure levels are decreased from the Low setting fan speed using the wireless remote controller.

Outdoor Unit Quiet Operation

Outdoor unit operating sound pressure levels are decreased from the rated operation sound using the wireless remote controller.

Cleaning filter operation

After operation stops, this function automatically brushes dust off the prefilter and collects it in a box. This helps to maintain filter performance and energy efficiency.Cleaning Filter Operation.

Air-Purifying Filter

This filter removes impurities such as dust, pollen and cigarette smoke as well as bacteria and viruses from the air.

Titanium apatite deodorising filter

While the filter’s micron-level fibres trap dust, titanium apatite effectively adsorbs odours and allergens, as well as deodorises odours. This filter delivers consistent performance for approximately three years if it is washed with water once every six month.

Mould-Proof Operation

Automatically runs fan-only operation for 1 hour when cooling or dry operation is stopped. This airflow prevents the generation of mould and mould odours inside the indoor unit.

Wipe-Clean Flat Panel

The flat panel design can be cleaned with only the single pass of a cloth across its smooth surface. The flat panel can also be easily removed for more thorough cleaning.

Installation position setting

Optimal control of the horizontal airflow direction no matter where is your indoor unit installed

Information display

The LCD displays various information including total energy use over several days

Indoor unit lamp brigntness setting

The brightness of operation lamp at indoor unit can be adjusted to High, Low or off.

Stanby electricity saving

This function reduce electricity that air conditioners requires while it’s not operate.
 

Econo Mode

This mode limits maximum running current and power consumption to prevents circuit breakers from being overloaded.

Inverter Powerful Operation

Inverter air conditioners operate at maximum capacity as soon as they start up. This burst of increased power allows them to reach the set temperature more quickly.

Wireless remote control with luminous button

Wireless remote control with luminous button

Daikin Mobile Controller (optional adaptor)

Mobile controller

Indoor Unit On/Off Switch

The unit can be conveniently started manually.

Comfort sleep timer

Keep temperature & Humidity at suitable level for comfortable sleep & fresh morning.

Quick Heating Timer

Quickly blows warm air when the HEATING operation starts in the morning and makes a warmth zone around the indoor units.

24-Hour On/Off Timer

Sets timer to start or stop within a 24-hour.The On timer and Off timer can be used in combination.

Timer operation

Automatically switching air conditioner on/off at night or in the morning.

Child Block

Lock the operation of remote controller to avoid children play it.

Auto-Restart

Automatically operates airconditioner & returns to the recent setting after power failure is restore.

Self diagnosis

Multi function codes are shown on the wireless remote controller for fast and easy maintenance.

Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins

Coating heat exchanger A thin acrylic resin layered to enhance the fin’s resistance to acid rain & salt corrosion.

Automatic defrosting

Defrost mode activate to maintain the effeciency of airconditioner.

Next-Generation Refrigerant R-32

Urusara 7 is the world's first air conditioner to use R-32 refrigerant. R-32 has zero ozone-layer depletion and also reduces the global warming potential by 70% compared to
R-22 or R-410A. The potential refrigeration capacity of R-32 is 1.6 times higher than R-22 or R-410A.

Specifications

Model Name Indoor Unit FTXZ25NVMV FTXZ35NVMV FTXZ50NVMV
Outdoor Unit RXZ25NVMV RXZ35NVMV RXZ50NVMV
Capacity Cooling Rated
(Min.-Max.)
kW 2.45 (0.6-3.9) 3.45 (0.6-5.3) 4.95 (0.6-5.8)
Heating 3.6 (0.6-7.5) 5.0 (0.6-9.0) 6.3 (0.6-9.4)
Cooling Rated
(Min.-Max.)
Btu/h 8,400 (2,000-13,300) 11,800 (2,000-18,100) 16,900 (2,000-19,800)
Heating 12,300 (2,000-25,600) 17,100 (2,000-30,700) 21,500 (2,000-32,100)
Power Consumption Cooling Rated
(Min.-Max.)
W 430 (110-880) 680 (110-1,330) 1,150 (110-1,600)
Heating 620 (100-2,010) 1,000 (100-2,530) 1,410 (100-2,640)
COP [tooltip] Cooling Rated
(Min.-Max.)
W/W 5.70 (5.45-4.43) 5.07 (5.45-3.98) 4.30 (5.45-3.63)
Heating 5.81 (6.00-3.73) 5.00 (6.00-3.56) 4.47 (6.00-3.56)
CSPF [tooltip] 7.04 6.89 6.29
Energy Efficiency Level [tooltip] Cooling ★★★★★ ★★★★★ ★★★★★
Heating ★★★★★ ★★★★★ ★★★★★
Indoor Unit FTXZ25NVMV FTXZ35NVMV FTXZ50NVMV
Sound Pressure Levels (H/L/SL) Cooling dB(A) 38/26/19 42/27/19 47/30/23
Heating 39/28/19 42/29/19 44/31/24
Dimensions (H x W x D) mm 295 x 798 x 370
Outdoor Unit RXZ25NVMV RXZ35NVMV RXZ50NVMV
Sound Pressure Levels (H) Cooling dB(A) 46 48 49
Heating 46 48 50
Dimensions (H x W x D) mm 595 x 795 x 300

Measurement conditions

  • 1.Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m.
  • 2.Heating Capacity is based on: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; piping length 7.5 m.
  • 3.Sound pressure levels are based on the temperature conditions 1 and 2 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
Catalog Catalog Where to buyWhere to buy
Back to top