Skip to main content

VIETNAM

FTXZ Series (Urusara 7)

  • Inverter
  • Heat Pump
  • R-32

Urusara 7 brings you to a new level of comfort by offering a unique, total comfort experience for any lifestyle. Latest advances in Japanese air conditioning technology is now at your fingertips.

  • Energy saving
  • Next-generation refrigerant
  • Humidity control
  • Airflow control
  • Designed in Japan
  • Air purification
  • Automatic filter cleaning

Download Catalogue

  • Note: The star energy label, issued by the Ministry of Industry and Trade of Vietnam, shows the consumers, level of air conditioner's energy efficiency.

Features

Energy saving

Urusara 7 achieves high COPs of 4.30 to 5.70 (CSPF of 6.29 to 7.04) during cooling operation thanks to Daikin's combined energy saving technologies and DC Inverter Power Control.

Next-Generation Refrigerant R-32

Urusara 7 is the world's first air conditioner to use R-32 refrigerant*1. R-32 has zero ozone-layer depletion and also reduces the global warming potential by 70% compared to
R-22 or R-410A. The potential refrigeration capacity of R-32 is 1.6 times higher than R-22 or R-410A.*2

  • *1 For residential-use wall-mounted type air conditioners as of November 2012, when Daikin launched Urusara 7 in Japanese market.
  • *2
    • Source: Values for 100 year global warming potential (GWP) from IPCC Fourth Assessment Report. Comparative 100 year GWP: HFC410A, 2,090; HFC32, 675.

Airflow Control

Urusara 7 circulates airflow and prevents temperature fluctuations even in large spaces.

Coanda Effect

The effect causes the airflow direction to alter along the surface of an object. Daikin has used it in Urusara 7 to provide greater airflow along the ceiling.

Double Air Intake

The indoor unit features air intakes on both the top and bottom. The double intakes maintain a large airflow volume by drawing in additional air from the bottom intake.

Humidity Control

By controlling humidity as well as temperature, Urusara 7 provides dehumidifying choices like you have never experienced before.

  • *This is is an in-house test using models for the Japanese market.
    • Test conditions: Continuous operation with discharged airflow temp. 26°C, dehumidifying volume 300cc/h in a thermostatic chamber with indoor temp. 28°C, indoor humidity 60%, outdoor temp. 28°C.

Designed in Japan

Inspired by Japanese folding fan “Ogi”, this innovative design wins Red Dot Award: Product Design 2013.

Air Purification

Urusara 7 provides better indoor air quality using streamer technology.

Streamer discharge decomposes bacteria and mold adsorbed on the filter by irradiating them with an advanced plasma electric discharge. It provides highly effective oxidative decomposition.

Automatic Filter Cleaning

After operation stops, this function automatically brushes dust off the prefilter and collects it in the installed dust box. Cleaning automatically starts after 18 hours of cumulative operation.

Specifications

Model Name Indoor Unit FTXZ25NVMV FTXZ35NVMV FTXZ50NVMV
Outdoor Unit RXZ25NVMV RXZ35NVMV RXZ50NVMV
Capacity Cooling Rated
(Min.-Max.)
kW 2.45 (0.6-3.9) 3.45 (0.6-5.3) 4.95 (0.6-5.8)
Heating 3.6 (0.6-7.5) 5.0 (0.6-9.0) 6.3 (0.6-9.4)
Cooling Rated
(Min.-Max.)
Btu/h 8,400 (2,000-13,300) 11,800 (2,000-18,100) 16,900 (2,000-19,800)
Heating 12,300 (2,000-25,600) 17,100 (2,000-30,700) 21,500 (2,000-32,100)
Power Consumption Cooling Rated
(Min.-Max.)
W 430 (110-880) 680 (110-1,330) 1,150 (110-1,600)
Heating 620 (100-2,010) 1,000 (100-2,530) 1,410 (100-2,640)
COP [tooltip] Cooling Rated
(Min.-Max.)
W/W 5.70 (5.45-4.43) 5.07 (5.45-3.98) 4.30 (5.45-3.63)
Heating 5.81 (6.00-3.73) 5.00 (6.00-3.56) 4.47 (6.00-3.56)
CSPF [tooltip] 7.04 6.89 6.29
Energy Efficiency Level [tooltip] Cooling ★★★★★ ★★★★★ ★★★★★
Heating ★★★★★ ★★★★★ ★★★★★
Indoor Unit FTXZ25NVMV FTXZ35NVMV FTXZ50NVMV
Sound Pressure Levels (H/L/SL) Cooling dB(A) 38/26/19 42/27/19 47/30/23
Heating 39/28/19 42/29/19 44/31/24
Dimensions (H x W x D) mm 295 x 798 x 370
Outdoor Unit RXZ25NVMV RXZ35NVMV RXZ50NVMV
Sound Pressure Levels (H) Cooling dB(A) 46 48 49
Heating 46 48 50
Dimensions (H x W x D) mm 595 x 795 x 300

Measurement conditions

  • 1. Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m.
  • 2. Heating Capacity is based on: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; piping length 7.5 m.
  • 3. Sound pressure levels are based on the temperature conditions 1 and 2 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

Split LineupSplit

Flagship (Inverter)

  • Heat Pump
  • R-32

Inverter

High Efficiency Type

  • Cooling Only
  • R-32
  • Heat pump
  • R-32
  • Heat Pump
  • R-410A
  • Cooling Only
  • R-410A

Standard Efficiency Type

  • Cooling Only
  • R-32
  • Heat Pump
  • R-32
  • Heat Pump
  • R-32

Non-Inverter

High Efficiency Type

  • Cooling Only
  • R-32

Standard Efficiency Type

  • Cooling Only
  • R-410A
  • Cooling Only
  • R-32
Go To Page Top