Inverter Heat Pump

Specially designed for shops, restaurants and small offices, the series meet all of your needs with full lineup of inverters for various types of indoor units and power supplies.

  • Inverter technology
  • Wide variety of indoor units
  • Anti-Corrosion Treatment for Outdoor Unit Heat Exchanger.
  • Navigation remote with Simple operation, Weekly Schedule timer
Download Catalogue
Where to buyWhere to buy Compare ProductsCompare Products

Features

High COP

Thanks to the combination of energy saving technologies, this series achieves COPs of 3.00 to 3.94.

Wide Variety of Indoor Units

Daikin meets your needs with this full lineup of inverters for various types of indoor units and power supplies.

Comfort Airflow Mode

Enhanced comfort with Inverter. Inverter performs variable control of frequency, which determines air conditioner's power performance.

Compact design for space saving

Compared to the previous non-inverter series, Outdoor units are much more compact with the height reduced to only 990 mm. Easy installation in place with limited places but still achieve higher CSPF.

Navigation Remote with Simple Operation, Weekly Schedule Timer

Simple, modern designed with fresh white color matches your interior design Easy to use and smoother operation by following the indications

Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins

To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit

Specifications

Ceiling Mounted Cassette (Round Flow) Type

Cassette air conditioner with 360° uniform airflow sets the standard

  • Avoids uneven temperature and discomfort caused by drafts
  • Comfort enhanced by Round Flow
  • Adapts easily to the installation space
  • Compact body and quiet operation
  • Quick and easy to install
  • Easier to maintain
  • Panel size is same for all models: makes it easy to maintain a neat appearance when multiple, units are installed.
 
  71 100
Model Indoor unit FCF71CVM FCF100CVM
Outdoor unit RZA71BV2V RZA100BV2V
Power supply 1 Phase, 220V, 50Hz
Cooling capacity *1,2
Rated (Min. - Max.)
kW 7.1 (3.2-8.0) 10.0 (5.0-11.2)
Btu/h 24,200 (10,900-27,300) 34,100 (17,100-38,200)
Heating capacity *1,2
Rated (Min. - Max.)
kW 7.1 (3.2-8.0) 10.0 (5.0-11.2)
Btu/h 24,200 (10,900-27,300) 34,100 (17,100-38,200)
Power consumption Cooling kW 1.92 2.63
Heating 1.58 2.38
COP Cooling W/W 3.70 3.80
Heating 4.49 4.20
CSPF Heating Wh/Wh 5.75 5.41
Indoor unit FCF71CVM FCF100CVM
Sound level (H / HM / M / ML / L) dB(A) 37.0 / 34.5 / 32.0 / 29.5 / 27.5 45.0 / 41.5 / 38.0 / 35.0 / 32.5
Dimensions (HxWxD) mm 256 X 840 X 840 298 X 840 X 840
Weight Kg 22 24
Outdoor unit RZA71BV2V RZA100BV2V
Sound level *3 Cooling/Heating dB(A) 48 / 50 51 / 53
Dimensions (HxWxD) mm 990 X 940 X 320
Weight Kg 73 74
Note:

*1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).

*2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)

*3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.

 

Ceiling Suspended Type

Comfortable airflow travels throughout the room
  • The technology of the DC fan motor, wide sirocco fan, and large heat exchanger combine for greater airflow and quiet operation.
  • Sophisticated design
  • Quiet operation
  • Installation flexibility for freedom of design
  • Easy maintenance
 
71 100
Model Indoor unit FHA71BVMV FHA100BVMV
Outdoor unit RZA71BV2V RZA100BV2V
Power supply 1 Phase, 220V, 50Hz
Cooling capacity *1,2
Rated (Min. - Max.)
kW 7.1 (3.2-8.0) 10.0 (5.0-11.2)
Btu/h 24,200 (10,900-27,300) 34,100 (17,100-38,200)
Heating capacity *1,2
Rated (Min. - Max.)
kW 7.1 (3.2-8.0) 10.0 (5.0-11.2)
Btu/h 24,200 (10,900-27,300) 34,100 (17,100-38,200)
Power consumption Cooling kW 2.22 2.86
Heating 1.82 2.50
COP Cooling W/W 3.20 3.50
Heating 3.90 4.00
CSPF Cooling Wh/Wh 5.69 5.36
Indoor unit FHA71BVMV FHA100BVMV
Sound level (H / M / L) dB(A) 38.0 / 37.0 / 36.0 / 35.0 / 34.0 42.0 / 40.0 / 38.0 / 36.0 / 34.0
Dimensions (HxWxD) mm 235 X 1270 X 690 235 X 1590 X 690
Weight Kg 32 38
Outdoor unit RZA71BV2V RZA100BV2V
Sound level *3 Cooling/Heating dB(A) 48 / 50 51 / 53
Dimensions (HxWxD) mm 990 X 940 X 320
Weight Kg 73 74
Note:

*1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).

*2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)

*3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.

 

Duct Connection Middle Static Pressure Type

Enhance comfort using cleverly placed ducts.

  • Increased freedom of design thanks to variable control over external static pressure
  • Thin, lightweight indoor unit makes delivery and installation easy.
  • Quiet operation
  • Easy maintenance
  • Two selectable temperature-sensors
 
71 100
Model Indoor unit FBA71BVMA FBA100BVMA
Outdoor unit RZA71BV2V RZA100BV2V
Power supply 1 Phase, 220V, 50Hz
Cooling capacity *1,2
Rated (Min. - Max.)
kW 7.1 (3.2-8.0) 10.0 (5.0-11.2)
Btu/h 24,200 (10,900-27,300) 34,100 (17,100-38,200)
Heating capacity *1,2
Rated (Min. - Max.)
kW 7.1 (3.2-8.0) 10.0 (5.0-11.2)
Btu/h 24,200 (10,900-27,300) 34,100 (17,100-38,200)
Power consumption Cooling kW 2.22 2.82
Heating 2.22 3.55
COP Cooling W/W 3.20 3.55
Heating 3.20 3.55
CSPF Cooling Wh/Wh 5.69 5.36
Indoor unit FBA71BVMA FBA100BVMA
Sound level (H / M / L) dB(A) 38.0 / 35.0 / 33.0
Dimensions (HxWxD) mm 245 X 1000 X 800 245 X 1400 X 800
Weight Kg 37 47
Outdoor unit RZA71BV2V RZA100BV2V
Sound level *3 Cooling/Heating dB(A) 48 / 50 51 / 53
Dimensions (HxWxD) mm 990 X 940 X 320
Weight Kg 73 74
Note:

*1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).

*2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)

*3 Capacities are net, including a deduction for cooling for indoor fan motor heat.

*4 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.

 

Floor Standing Type

Airflow control for more comfort

  • Auto swing direction is selectable from 3 patterns (Wide swing toward the front, swing on the left side, swing on the right side) to suit the layout of the room (Applicable when BRC1E62 is used.)
  • Independent up-and-down airflow directions facilitate even room temperature and help save energy (by hand).
  • DC fan motor improves efficiency.
  • Quiet operation
  • Quick and easy installation and maintenance
  • Comfortable fan speed control
 
  50 60 71 100
Model name Indoor Unit FVQ50CVEB FVQ60CVEB FVQ71CVEB FVQ100CVEB
Outdoor Unit RZQS50AV1 RZQS60AV1 RZQ71LV1 RZQ100LV1
Power supply Outdoor Unit 1 Phase, 220 - 240 V, 50Hz
Cooling Capacity1,3 Rated (Min. - Max.) kW 5.0
(3.2-5.6)
5.8
(3.2-6.0)
7.1
(3.2-8.0)
10.0
(5.0-11.2)
Btu/h 17,100
(10,900-19,100)
19,800
(10,900-20,500)
24,200
(10,900-27,300)
34,100
(17,100-38,200)
Heating Capacity2,3 Rated (Min.- Max.) kW 6.0
(3.5-7.0)
7.0
(3.5-8.0)
8.0
(3.5-9.0)
11.2
(5.1-12.8)
Btu/h 20,500
(11,900-23,900)
23,900
(11,900-27,300)
27,300
(11,900-30,700)
38,200
(17,400-43,700)
Power consumption Cooling1 kW 1.27 1.78 2.33 3.28
Heating2 1.52 2.15 2.61 3.67
COP Cooling W/W 3.94 3.26 3.05 3.05
Heating 3.94 3.26 3.07 3.05
Indoor unit Sound level (H/M/L) dB(A) 43/41/38 50/47/44
Dimensions (HxWxD) mm 1,850x600x270 1,850x600x350
Weight Kg 39 47
Outdoor unit Sound level
(Cooling/Heating/Night mode)
dB(A) 48/50/44 49/51/45 51/53/47
Dimensions (HxWxD) mm 770x900x320 990x940x320
Weight Kg 64 75
  125 140 100 125 140
Model name Indoor Unit FVQ125CVEB FVQ140CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB
Outdoor Unit RZQ125LV1 RZQ140LV1 RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A
Power supply Outdoor Unit 1 Phase, 220 - 240 V, 50Hz 3 Phase, 415 V, 50Hz
Cooling Capacity1,3 Rated (Min. - Max.) kW 12.5
(5.7-14.0)
13.5
(6.2-15.5)
10.0
(5.0-11.2)
12.5
(5.7-14.0)
13.5
(6.2-15.4)
Btu/h 42,700
(19,500-47,800)
46,100
(21,200-52,900)
34,100
(17,100-38,200)
42,700
(19,500-47,800)
46,100
(21,200-52,900)
Heating Capacity2,3 Rated (Min.- Max.) kW 14.0
(6.0-16.2)
16.0
(6.2-18.0)
11.2
(5.1-12.8)
14.0
(6.0-16.2)
16.0
(6.2-18.0)
Btu/h 47,800
(20,500-55,300)
54,600
(21,200-61,400)
38,200
(17,400-43,700)
47,800
(20,500-55,300)
54,600
(21,200-61,400)
Power consumption Cooling1 kW 4.39 5.4 3.28 4.39 5.4
Heating2 4.26 5.28 3.67 4.26 5.28
COP Cooling W/W 2.85 2.50 3.05 2.85 2.50
Heating 3.29 3.03 3.05 3.29 3.03
Indoor unit Sound level (H/M/L) dB(A) 51/48/46 53/51/48 50/47/44 51/48/46 53/51/48
Dimensions (HxWxD) mm 1,850x600x350
Weight Kg 47
Outdoor unit Sound level (Cooling/Heating/Night mode) dB(A) 51/53/47 54/56/50 49/51/45 50/52/45 50/52/46
Dimensions (HxWxD) mm 1,170x900x320 1,430x940x320 1,345x900x320
Weight Kg 98 108 108
 Note:
 
*1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
 
*2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
 
*3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions
Catalog Catalog Where to buyWhere to buy
Back to top