Non-Inverter Heat Pump

Daikin's SkyAir is the choice to bring high quality air conditioning to stores and offices like this. Thanks to its many advantages, the SkyAir enjoys an excellent reputation throughout the world wherever it is used.

  • Quiet operation
  • Easy to use
  • Flexible installation
Download Catalogue
Where to buyWhere to buy Compare ProductsCompare Products

Features

Wide Variety of Indoor Units

Daikin meets your needs with full lineup for various types of indoor units (Ceiling mounted cassette type; Ceiling suspended type; Duct connection type, Floor standing type) and power supplies

Compact and Lightweight

Reduced installation work thanks to light, compact outdoor unit.

Quiet operation

Depending on types of indoor units, sound level can range from 28 dB (A) to 53dB (A). Outdoor Unit operation sound is from 50 dB(A) to 56dB(A)

Easy Installation and Maintenance

Pre-charged for up to 30 metres -Long piping length -4-direction piping offers greater layout freedom -Removable part of bottom frame makes the piping work easier -Facilitates pump down

Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins

To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.

Specifications

Ceiling Mounted Cassette Type

Cassette air conditioner with 360° uniform airflow sets the standard

  • Avoids uneven temperature and discomfort caused by drafts
  • Comfort enhanced by Round Flow
  • Adapts easily to the installation space
  • Compact body and quiet operation
  • Quick and easy to install
  • Easier to maintenance
  • Panel size is same for all models: makes it easy to maintain a neat appearance when multiple, units are installed.
 
  71 100 125 140
Model name Indoor Unit FCQ71KAVEA FCQ100KAVEA FCQ125AVEA FCQ140KAVEA
Outdoor Unit V1 RQ71MV1 RQ100MV1    
Outdoor Unit Y1 RQ71MY1 RQ100MY1 RQ125MY1 RQ140MY1
Power supply Outdoor Unit V1 1 Phase, 220 - 240 V, 50Hz    
Outdoor Unit Y1 3 Phase, 380-415 V,50Hz
Cooling Capacity1,3 Rated (Min. - Max.) kW 7.1 10.0 12.5 14.0
Btu/h 24,200 34,100 42,700 47,800
Heating Capacity2,3 Rated (Min.- Max.) kW 8.0 11.2 14.0 16.0
Btu/h 27,300 38,200 47,800 54,600
Power consumption Cooling1 kW 2.72 3.83 4.66 4.91
Heating2 2.85 3.75 5.06 4.97
COP Cooling W/W 2.61 2.61 2.68 2.85
Heating 2.81 2.99 2.77 3.22
Indoor unit Sound level (H/M/L) dB(A) 35/31.5/28 43/37.5/32 44/39/34 44/40/36
Dimensions (HxWxD) mm 256x840x840 298x840x840
Weight Kg 21 24
Outdoor unit Sound level (Cooling/Heating) dB (A) 50/52 53/56 54/56
Dimensions (HxWxD) mm 770x900x320 1,170x900x320
Weight Kg 84 (V1), 83 (Y1) 103 (V1), 101 (Y1) 108 101
Note: 

*1 Rated cooling capacities are based on the following conditions:

  • *1a Suction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5m (horizontal).
  • *1b Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5m (horizontal). (RY71LU-RY140LU is 7.5 m.)

*2 Rated heating capacities are based on the following conditions: Suction temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY140LU is 7.5 m.)

*3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.

Ceiling Suspended Type

Comfortable airflow travels throughout the room

  • The technology of the DC fan motor, wide sirocco fan, and large heat exchanger combine for greater airflow and quiet operation.
  • Sophisticated design
  • Quiet operation
  • Installation flexibility for freedom of design
  • Easy maintenance
 
  71 100 125 140
Model name Indoor Unit FHQ71DAVMA FHQ100DAVMA FHQ125DAVMA FHQ140DAVMA
Outdoor Unit V1 RQ71MV1 RQ100MV1 RQ125MY1 RQ140MY1
Outdoor Unit Y1 RQ71MY1 RQ100MY1
Power supply Outdoor Unit V1 1 Phase, 220 - 240 V, 50Hz  
Outdoor Unit Y1 3 Phase, 380-415 V,50Hz
Cooling Capacity1,3 Rated (Min. - Max.) kW 7.1 10.0 12.5 14.0
Btu/h 24,200 34,100 42,700 47,800
Heating Capacity2,3 Rated (Min.- Max.) kW 8.0 11.2 14.0 16.0
Btu/h 27,300 38,200 47,800 54,600
Power consumption Cooling1 kW 2.7 3.75 4.51 4.87
Heating2 2.85 4.13 5.00 4.94
COP Cooling W/W 2.63 2.67 2.77 2.87
Heating 2.81 2.71 2.80 3.24
Indoor unit Sound level (H/M/L) dB(A) 38/36/34 42/38/34 44/41/37 46/42/38
Dimensions (HxWxD) mm 235x1,270x690 235x1,590x690
Weight Kg 32 38
Outdoor unit Sound level (Cooling/Heating) dB (A) 50/52 53/56 54/56
Dimensions (HxWxD) mm 770x900x320 1,170x900x320
Weight Kg 84 (V1), 83 (Y1) 103 (V1), 101 (Y1) 108 101
Note:

*1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).

*2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)

*3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.

Duct Connection Middle Static Pressure Type

Unit can be mounted in the ceiling and air can be delivered freely by duct.

  • Freedom of layout.
  • Quiet operation
 
  71 100 125 140
Model name Indoor Unit FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE
Outdoor Unit V1 RQ71MV1 RQ100MV1    
Outdoor Unit Y1 RQ71MY1 RQ100MY1 RQ125MY1 RQ140MY1
Power supply Outdoor Unit V1 1 Phase, 220 - 240 V, 50Hz    
Outdoor Unit Y1 3 Phase, 380-415 V,50Hz
Cooling Capacity1,3 Rated (Min. - Max.) kW 7.1 10.0 12.5 14.0
Btu/h 24,200 34,100 42,700 47,800
Heating Capacity2,3 Rated (Min.- Max.) kW 8.0 11.2 14.0 16.0
Btu/h 27,300 38,200 47,800 54,600
Power consumption Cooling1 kW 2.71 3.78 4.67 5.02
Heating2 2.49 3.91 4.52 4.91
COP Cooling W/W 2.62 2.65 2.68 2.79
Heating 3.21 2.86 3.10 3.26
Indoor unit Sound level (H/M/L) dB(A) 38/35/33 38/35.5/33 40/37.5/35
Dimensions (HxWxD) mm 245x1,000x800 245x1,400x800
Weight Kg 37 47
Outdoor unit Sound level (Cooling/Heating) dB (A) 50/52 53/56 54/56
Dimensions (HxWxD) mm 770x900x320 1,170x900x320
Weight Kg 84 (V1), 83 (Y1) 103 (V1), 101 (Y1) 108 101
Note:

*1 Rated cooling capacities are based on the following conditions:

  • *1a Indoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal).
  • *1b Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY125LU is 7.5 m.)

*2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY125LU is 7.5 m.)

*3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.

Made in Malaysia
 

An ideal way of space saving with style and functionality, with it’s ease of installation, it is suited to be installed in offices, commercial shops, restaurants, showrooms and mosques.

  • Sleek, stylish and modern to blend into any environment
  • High gloss finishing for easy cleaning
  • Slim profile
  • Stylish black control panel with white LED light for crisp clear display
  • Compact & Easy-to-Use Handset
 
  71 100 125 140
Model Name Indoor Unit FVQN71AXV1 FVQN100AXV1 FVQN125AXV1 FVQN140AXV1
Outdoor Unit RQ71CXV1 RQ100DXY1 RQ125DXY1 RQ140DXY1
Cooling Capacity kW 8.21 11.72 13.19 16.12
Btu/h 28000 40000 45000 55000
Heating Capacity kW 8.06 12.31 13.48 16
Btu/h 27500 42000 46000 54500
Power Consumption Cooling kW 2840 4050 4680 5490
Heating 2520 3920 4465 5300
Indoor Unit Sound Pressure Levels dB(A) 44/42/39 49/47/44 50/48/46 54/53/51
Dimensions
(H x W x D)
mm 1850 x 600 x 270 1850 x 600 x 350
Outdoor Unit Sound Pressure Levels dB(A) 58 58 60 65
Dimensions
(H x W x D)
mm 753 x 855 x 328 852 x 1030 x 400
Note:

*1 Rated cooling capacities are based on the following conditions:

  • *1a Indoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal).
  • *1b Indoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).

*2Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB; outdoor temp., 7°CDB, 6°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).

*3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.

Floor Standing

Made in Thailand
 

The floor standing configuration means this product is easy to install and maintain. It can also be installed under high ceilings.

  • Quite operation
  • Auto-swing delivers comfort to every corner of the room
  • Easy to operate, handy LCD control panel
  • Easy to install and service
 
  71 100 125 140
Model name Indoor Unit FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB
Outdoor Unit V1 RQ71MV1 RQ100MV1    
Outdoor Unit Y1 RQ71MY1 RQ100MY1 RQ125MY1 RQ140MY1
Power supply Outdoor Unit V1 1 Phase, 220 - 240 V, 50Hz    
Outdoor Unit Y1 3 Phase, 380-415 V,50Hz
Cooling Capacity1,3 Rated (Min. - Max.) kW 7.1 10.0 12.5 14.0
Btu/h 24,200 34,100 42,700 47,800
Heating Capacity2,3 Rated (Min.- Max.) kW 8.0 11.2 14.0 16.0
Btu/h 27,300 38,200 47,800 54,600
Power consumption Cooling1 kW 2.87 3.95 4.79 5.44
Heating2 3.04 3.75 4.67 5.28
COP Cooling W/W 2.47 2.53 2.57 2.57
Heating 2.63 2.99 3.00 3.03
Indoor unit Sound level (H/M/L) dB(A) 43/41/38 50/47/44 51/48/46 53/51/48
Dimensions (HxWxD) mm 1,850x600x270 1,850x600x350
Weight Kg 39 47
Outdoor unit Sound level (Cooling/Heating) dB (A) 50/52 53/56 54/56
Dimensions (HxWxD) mm 770x900x320 1,170x900x320
Weight Kg 84 (V1), 83 (Y1) 103 (V1), 101 (Y1) 108 101
Note:

*1 Rated cooling capacities are based on the following conditions:

  • *1a Indoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal).
  • *1b Indoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).

*2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB; outdoor temp., 7°CDB, 6°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).

*3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.