Middle Static Presssure Ceilling Mounted Ducted Type

Slim and compact design for easy and flexible installation

  • Compact design suited to use in narrow ceillings
  • Adjustable external static pressure
  • Quiet operation
  • Adjustable airflow rate
Download Catalogue

Where to buyWhere to buy

Features

Installation flexibility

  • Slim design, only 245 mm in height.
  • Standard DC drain pump with 850mm lift.
  • Both rear suction or bottom suction possible.

Adjustable external static pressure

using the DC fan, the external static pressure can be controlled with a range of 30 Pa to 150 Pa.

Quiet operation

Low operation sound level with switchable airflow rate from 3-step control.

Easy Maintenance

Inspection and cleaning is facilitated by separating the drain pipe and inspection opening and by the drain pan maintenance check hole.

Specifications

Model FXSQ20PVE FXSQ25PVE FXSQ32PVE FXSQ40PVE FXSQ50PVE
Cooling Capacity Btu/h 7,500 9,600 12,300 15,400 19,100
kW 2.2 2.8 3.6 4.5 5.6
Heating Capacity Btu/h 8,500 10,900 13,600 17,100 21,500
kW 2.2 3.2 4.0 5.0 6.3
Power Consumption (kW) Cooling 0.058 0.058 0.066 0.101 0.075
Heating 0.053 0.053 0.061 0.096 0.07
Sound Level (HH/H/L) dB(A) 33/30/28 34/32/30 36/33/30
External static pressure Pa 30-150 (50) 50-150 (50)
Dimensions (H x W x D) mm 245x550x800 245x700x800 245x1,000x800
Model FXSQ63PVE FXSQ80PVE FXSQ100PVE FXSQ125PVE FXSQ140PVE
Cooling Capacity Btu/h 24,200 30,700 38,200 47,800 54,600
kW 7.1 9.0 11.2 14.0 16.0
Heating Capacity Btu/h 27,300 34,100 42,700 54,600 61,400
kW 8 10.0 12.5 16.0 18.0
Power Consumption (kW) Cooling 0.106 0.126 0.151 0.206 0.222
Heating 0.101 0.121 0.146 0.201 0.217
Sound Level (HH/H/L) dB(A) 34/32/29 37.5/34/30 39/35/32 42/38.5/35 43/40/36
External static pressure Pa 50-150 (50) 50-140 (50)
Dimensions (H x W x D) mm 245x1,000x800 245x1,400x800 245x1,550x800
Note: Specifications are based on the following conditions;
  • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
  • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
  • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
  • Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
    During actual operation, these values are normally somewhat higher as a result of ambient conditions.
  • *1 Power consumption values are based on conditions of rated external static pressure.
  • *2 External static pressure can be modified using a remote controller that offers seven (FXMQ20-32P), thirteen (FXMQ40P), fourteen (FXMQ50-125P) or ten (FXMQ140P) levels of control. These values indicate the lowest and highest possible static pressures. The standard static pressure is 50 Pa.