VRV III-Q

Designed for replacement use, VRV III-Q is a quick, easy installation, and energy saving air conditioning.

  • Simple use of existing refrigerant piping
  • Refrigerant charging completed with just one switch.
  • Automatic measurement of the exact volume necessary for refrigerant charging.
Download Catalogue
Where to buyWhere to buy

Features

Space Saving

  • Significantly more compact outdoor unit enables the effective use of limited space.
  • Compact design enables the effective use of space taken up by existing machinery.

Energy Saving with High COP

Thanks to advanced features such as the heat exchanger, the grille and the dual DC fans, VRV III-Q has reached a higher level of efficiency.

Simple Use of Existing Refrigerant Piping

  • Reduces installation time: A function automatically deals with dirt (contamination) inside piping during refrigerant charging, eliminating the work involved in cleaning.
  • Enables smooth replacement of air conditioning with less effect on operations and users in the building

System Flexibility

  • More indoor units can be connected in a single system, enabling consolidation of existing piping.
  • The number of connectable indoor units has been drastically increased from 30 to 64.

Specifications

Model RQQ8PY1 RQQ10PY1 RQQ12PY1 RQQ14PY1 RQQ16PY1
Combination Units - - - - -
- - - - -
- - - - -
Cooling Capacity Btu/h*1 76,800 96,200 115,000 137,000 155,000
kW*2 22.4 28 33.5 40.0 45.0
Power Consumption*2 kW 5.24 7.64 10.1 11.6 13.6
Dimensions (H x W x D) mm 1,680 x 930 x 765 1,680 x 1,240 x 765
Sound Level dB(A) 57 58 60 60 60
Model RQQ18PY1 RQQ20PY1 RQQ22PY1 RQQ24PY1
Combination Units RQQ8PY1 RQQ8PY1 RQQ10PY1 RQQ12PY1
RQQ10PY1 RQQ12PY1 RQQ12PY1 RQQ12PY1
- - - -
Cooling Capacity Btu/h*1 173,000 192,000 211,000 230,000
kW*2 50.4 55.9 61.5 67
Power Consumption*2 kW 12.9 15.4 17.8 20.2
Dimensions (H x W x D) mm (1,680 x 930 x 765)+(1,680 x 930 x 765)
Sound Level dB(A) 61 62 63 63
Model RQQ26PY1 RQQ28PY1 RQQ30PY1 RQQ32PY1
Combination Units RQQ10PY1 RQQ12PY1 RQQ14PY1 RQQ16PY1
RQQ16PY1 RQQ16PY1 RQQ16PY1 RQQ16PY1
- - - -
Cooling Capacity Btu/h*1 251,000 270,000 292,000 310,000
kW*2 73 78.5 85.0 90.0
Power Consumption*2 kW 21.3 23.7 25.2 27.2
Dimensions (H x W x D) mm (1,680 x 930 x 765)+(1,680 x 1,240 x 765) (1,680 x 1,240 x 765)+(1,680 x 1,240 x 765)
Sound Level dB(A) 63 63 63 63
Model RQQ34PY1 RQQ36PY1 RQQ38PY1 RQQ40PY1
Combination Units RQQ10PY1 RQQ10PY1 RQQ10PY1 RQQ12PY1
RQQ10PY1 RQQ10PY1 RQQ12PY1 RQQ12PY1
RQQ14PY1 RQQ16PY1 RQQ16PY1 RQQ16PY1
Cooling Capacity Btu/h*1 329,000 348,000 368,000 386,000
kW*2 96.0 101 107 112
Power Consumption*2 kW 26.9 28.9 31.4 33.8
Dimensions (H x W x D) mm (1,680 x 930 x 765)+(1,680 x 930 x 765)+(1,680 x 1,240 x 765)
Sound Level dB(A) 64 64 65 65
Model RQQ42PY1 RQQ44PY1 RQQ46PY1 RQQ48PY1
Combination Units RQQ10PY1 RQQ12PY1 RQQ14PY1 RQQ16PY1
RQQ16PY1 RQQ16PY1 RQQ16PY1 RQQ16PY1
RQQ16PY1 RQQ16PY1 RQQ16PY1 RQQ16PY1
Cooling Capacity Btu/h*1 406,000 427,000 447,000 464,000
kW*2 118 124 130 135
Power Consumption*2 kW 34.9 35.3 38.8 40.8
Dimensions (H x W x D) mm (1,680 x 930 x 765)+(1,680 x 1,240 x 765)
+(1,680 x 1,240 x 765)
(1,680 x 1,240 x 765)+(1,680 x 1,240 x 765)
+(1,680 x 1,240 x 765)
Sound Level dB(A) 65 65 65 65
Note: Specifications are based on the following conditions;
Cooling:
  • *1 Indoor temp.: 27°CDB, 19.5°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
  • *2 Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Sound level:
  • Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit center.
  • During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Model RQYQ8PY1 RQYQ10PY1 RQYQ12PY1 RQYQ14PY1 RQYQ16PY1
Combination Units - - - - -
- - - - -
- - - - -
Cooling Capacity Btu/h*1 76,800 96,200 115,000 137,000 155,000
kW*2 22.4 28.0 33.5 40.0 45.0
Heating Capacity kW 25.0 31.5 37.5 45.0 50.0
Power Consumption Cooling*2 kW 5.24 7.64 10.1 11.6 13.6
Heating 6.42 8.59 10.2 12.2 13.6
Dimensions (H x W x D) mm 1,680 x 930 x 765 1,680 x 1,240 x 765
Sound Level dB(A) 57 58 60 60 60
Model RQYQ18PY1 RQYQ20PY1 RQYQ22PY1 RQYQ24PY1
Combination Units RQYQ8PY1 RQYQ8PY1 RQYQ10PY1 RQYQ12PY1
RQYQ10PY1 RQYQ12PY1 RQYQ12PY1 RQYQ12PY1
- - - -
Cooling Capacity Btu/h*1 173,000 192,000 211,000 230,000
kW*2 50.4 55.9 61.5 67.0
Heating Capacity kW 56.5 62.5 69.0 75.0
Power Consumption Cooling*2 kW 12.9 15.4 17.8 20.2
Heating 15.1 16.7 18.8 20.4
Dimensions (H x W x D) mm (1,680 x 930 x 765)+(1,680 x 930 x 765)
Sound Level dB(A) 61 62 63 63
Model RQYQ26PY1 RQYQ28PY1 RQYQ30PY1 RQYQ32PY1
Combination Units RQYQ10PY1 RQYQ12PY1 RQYQ14PY1 RQYQ16PY1
RQYQ16PY1 RQYQ16PY1 RQYQ16PY1 RQYQ16PY1
- - - -
Cooling Capacity Btu/h*1 251,000 270,000 292,000 310,000
kW*2 73.0 78.5 85.0 90.0
Heating Capacity kW 81.5 87.5 95.0 100
Power Consumption Cooling*2 kW 21.3 23.7 25.2 27.2
Heating 22.2 23.8 25.8 27.2
Dimensions (H x W x D) mm (1,680 x 930 x 765)+(1,680 x 1,240 x 765) (1,680 x 1,240 x 765)+(1,680 x 1,240 x 765)
Sound Level dB(A) 63 63 63 63
Model RQYQ34PY1 RQYQ36PY1 RQYQ38PY1 RQYQ40PY1
Combination Units RQYQ10PY1 RQYQ10PY1 RQYQ10PY1 RQYQ12PY1
RQYQ10PY1 RQYQ10PY1 RQYQ12PY1 RQYQ12PY1
RQYQ14PY1 RQYQ16PY1 RQYQ16PY1 RQYQ16PY1
Cooling Capacity Btu/h*1 329,000 348,000 368,000 386,000
kW*2 96.0 101 107 112
Heating Capacity kW 108 113 119 125
Power Consumption Cooling*2 kW 26.9 28.9 31.4 33.8
Heating 29.4 30.8 32.4 34
Dimensions (H x W x D) mm (1,680 x 930 x 765)+(1,680 x 930 x 765)+(1,680 x 1,240 x 765)
Sound Level dB(A) 64 64 65 65
Model RQYQ42PY1 RQYQ44PY1 RQYQ46PY1 RQYQ48PY1
Combination Units RQYQ10PY1 RQYQ12PY1 RQYQ14PY1 RQYQ16PY1
RQYQ16PY1 RQYQ16PY1 RQYQ16PY1 RQYQ16PY1
RQYQ16PY1 RQYQ16PY1 RQYQ16PY1 RQYQ16PY1
Cooling Capacity Btu/h*1 406,000 427,000 447,000 464,000
kW*2 118 124 130 135
Heating Capacity kW 132 138 145 150
Power Consumption Cooling*2 kW 34.9 35.3 38.8 40.8
Heating 35.8 36 39.4 40.8
Dimensions (H x W x D) mm (1,680 x 930 x 765)+(1,680 x 1,240 x 765)+(1,680 x 1,240 x 765) (1,680 x 1,240 x 765)+(1,680 x 1,240 x 765)+(1,680 x 1,240 x 765)
Sound Level dB(A) 65 65 65 65
Note: Specifications are based on the following conditions;
Cooling:
  • *1 Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB.
  • *2 Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
 
Level difference: 0 m
 
Sound level:
  • Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
  • During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Lineup

Please take a look at the table below for the detailed information
regarding the appropriate combinations of indoor units and outdoor units.

VRV Combination Table
Back to top