VRV III-S

A special air conditioning system designed for small offices and shops

5S + 1E concept

  • Space saving
  • Sufficient capacity
  • Slim design
  • Sound-reduced operation
  • Single phase power supply
  • Easy installation
Download Catalogue
Where to buyWhere to buy

Features

Space Saving

Slim, compact and sufficient capacity: suitable for small offices and shops with capacities of 4, 5 and 6 HP

Sufficient Capacity - Wide Range of Choices

  • 3 models of outdoor unit
  • 14 types and 71 models of indoor unit

Slim Design

  • Only 200 mm in height, product can be installed in rooms with as little as 240 mm depth between the drop-ceiling and ceiling slab.

Sound-Reduced Operation

To reduce noise and realize comfortable operation, the latest technologies and features are applied to the outdoor units. Lower operation sound is achieved in cooling operation.

Single Phase Power Supply

Make possible for residential usage

Easy Installation

  • Easy wiring
  • Automatic test operation
  • Simple wiring and piping connection

Specifications

Model RXMQ4PVE RXMQ5PVE RXMQ6PVE
Cooling Capacity Btu/h 38,200 47,700 52,900
kW 11.2 14.0 15.5
Power Consumption kW 2.95 3.97 4.44
Dimensions (H x W x D) mm 1,345 x 900 x 320
Sound Level dB(A) 50 51 53
Note: Specifications are based on the following conditions;
  • Cooling: Indoor temp.: 27°CDB, 19.5°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5m, Level difference: 0m.
  • Sound level:
    Anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m.
    During actual operation, these values are normally somewhat higher as a result of ambient conditions.
  • Refrigerant charge is required.
Model RXYMQ4PVE RXYMQ5PVE RXYMQ6PVE
Cooling Capacity Btu/h 38,200 47,800 52,900
kW 11.2 14.0 15.5
Heating Capacity Btu/h 42,700 54,600 61,400
kW 12.5 16.0 18.0
Power Consumption Cooling mm 2.95 3.97 4.44
Heating dB(A) 3.27 4.09 4.82
Dimensions (H x W x D) mm 1,345 x 900 x 320
Sound Level (Cooling/Heating) dB(A) 50/52 51/53 53/55
Note: Specifications are based on the following conditions;
  • Cooling: Indoor temp.: 27°CDB, 19.5°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5m, Level difference: 0m.
  • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5m, Level difference: 0m.
  • Sound level:
    Anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m.
    During actual operation, these values are normally somewhat higher as a result of ambient conditions.
  • Refrigerant charge is required.

Lineup

Please take a look at the table below for the detailed information
regarding the appropriate combinations of indoor units and outdoor units.

VRV Combination Table