VRV IV-W

A water cooled intelligent individual air conditioning system which is suitable for tall multi-story buildings.

It utilizes water as a heat source. This unique system can perform as heat pump or heat recovery to any suitable application.

Download Catalogue
Where to buyWhere to buy

Features

Ease of Installation

Compact and lightweight outside unit

Weight of 149 kg and height of 1,000 mm make installation possible in buildings with limited space, or where no space is available for outside un

Stacked-configuration

Stacked-configuration in indoor installation is possible.

Enhanced Usability

  • A variety of functions that realizes easy installation and improve reliability: Pump interlock, DIII-NET employment, Auto address setting
  • Centralized interlocking function
  • 2 types of BS units for heat recovery can improve design flexibility.

Design Flexibility

2-stage heat recovery operation substantially improves energy efficiency and makes the system the ideal solution to the requirements of modern office buildings, where some areas may require cooling even in winter, depending on solar heat gain received and the number of people in the room.

Design flexibility and Simplified installation

  • Enhanced design flexibility: uses water as heat source, therefore optimal for large buildings, including tall, multi-story buildings, the system can tolerate water pressure of up to 1.96 Mpa.
  • Long refrigerant piping length:
    • Actual piping length: 120 m
    • Total piping length: 300 m
    • Equivalent piping length: 140 m
    • Level difference between the VRV IV-W and indoor units: 50 m

Specifications

Model RWEYQ6TYM RWEYQ8TYM RWEYQ10TYM RWEYQ12TYM
Combination units - - - -
- - - -
- - - -
Cooling capacity Btu/h 54,600 76,400 95,500 114,000
kW 16.0 22.4 28.0 33.5
Heating capacity kW 18.0 25.0 31.5 37.5
Power consumption Cooling kW 2.58 3.86 5.43 7.33
Heating 2.69 3.98 5.60 7.87
Dimensions
(H ⅹ W ⅹ D)
mm 1,000 x 780 x 550
Sound level dB(A) 49 50 51 53
Model RWEYQ14TYM RWEYQ16TYM RWEYQ18TYM RWEYQ20TYM
Combination units RWEYQ6TYM RWEYQ8TYM RWEYQ8TYM RWEYQ10TYM
RWEYQ8TYM RWEYQ8TYM RWEYQ10TYM RWEYQ10TYM
- - - -
Cooling capacity Btu/h 131,000 153,000 172,000 191,000
kW 38.4 44.8 50.4 56.0
Heating capacity kW 43.0 50.0 56.5 63.0
Power consumption Cooling kW 6.44 7.72 9.29 10.9
Heating 6.67 7.96 9.58 11.2
Dimensions
(H ⅹ W ⅹ D)
mm (1,000 x 780 x 550) x 2
Sound level dB(A) 53 54
Model RWEYQ22TYM RWEYQ24TYM RWEYQ26TYM RWEYQ28TYM
Combination units RWEYQ10TYM RWEYQ12TYM RWEYQ8TYM RWEYQ8TYM
RWEYQ12TYM RWEYQ12TYM RWEYQ8TYM RWEYQ10TYM
- - RWEYQ10TYM RWEYQ10TYM
Cooling capacity Btu/h 210,000 229,000 248,000 268,000
kW 61.5 67.0 72.8 78.4
Heating capacity kW 69.0 75.0 81.5 88.0
Power consumption Cooling kW 12.8 14.7 13.2 14.7
Heating 13.5 15.7 13.6 15.2
Dimensions
(H ⅹ W ⅹ D)
mm (1,000 x 780 x 550) x 2 (1,000 x 780 x 550) x 3
Sound level dB(A) 55 56 55 56
Model RWEYQ30TYM RWEYQ32TYM RWEYQ34TYM RWEYQ36TYM
Combination units RWEYQ10TYM RWEYQ10TYM RWEYQ10TYM RWEYQ12TYM
RWEYQ10TYM RWEYQ10TYM RWEYQ12TYM RWEYQ12TYM
RWEYQ10TYM RWEYQ12TYM RWEYQ12TYM RWEYQ12TYM
Cooling capacity Btu/h 287,000 305,000 324,000 345,000
kW 84.0 89.5 95.0 101
Heating capacity kW 94.5 101 107 113
Power consumption Cooling kW 16.3 18.2 20.1 22.0
Heating 16.8 19.1 21.3 23.6
Dimensions
(H ⅹ W ⅹ D)
mm (1,000 x 780 x 550) x 3
Sound level dB(A) 56 57 58
Note:
1. Specifications are based on the following conditions:
  • Cooling : Indoor temp.: 27ºCDB, 19ºCWB / inlet water temp.: 30ºC, Equivalent piping length: 7.5m, Level difference: 0m.
  • Heating : Indoor temp.: 20ºCDB / inlet water temp.: 20ºC, Equivalent piping length: 7.5m, Level difference: 0m.
2. This unit cannot be installed in the outdoors. Install indoors (Machine room, etc).
3. Hold ambient temperature at 0 – 40ºC and humidity at 80%RH or less. Heat rejection from the casing : 0.51 kW / 6 - 8 HP / hour, 0.58 kW / 10 - 12 HP / hour.
4. Connectable to closed type cooling tower only:
  • * 1: In the case of heat pump system, suction gas pipe is not used.
  • * 2: In the case of heat recovery system.
  • * 3: In the case of heat pump system.
    · Be sure to refer to the Engineering Data Book for facility design.