Note:

The star energy label, issued by the Ministry of Industry and Trade of Vietnam, shows the consumers, level of air conditioner's energy efficiency.

FTHF series

Coanda effect is the observed tendency of a moving gas or fluid leaving a nozzle of some kind to cling and follow nearby surfaces. We utilize this tendency by aiming the airflow at room surfaces, such as walls or ceilings.

  • Outstanding energy savings
  • Coanda effect with winds up to 9m
  • Titanium apatite photocatalytic air-purifying filter
  • Comfortable airflow, low sound level
  • Warm on winter days
Download Catalogue
Where to buyWhere to buy Compare ProductsCompare Products

Features

Power-Airflow Dual Flaps

The Power-Airflow Dual Flaps can flatten out during cooling operation to deliver cool air to the corners of a room. The flaps can direct warm air straight down to the floor during heating operation.

Power-Airflow Flap

The Power-Airflow Flap regulates the outlet aperture to an optimum shape

Wide-Angle Louvers

The Wide-Angle Louvers provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room. 

Vertical Auto-Swing (up and down)

This function automatically moves the flaps up and down to distribute air across a room.

Comfort Airflow Mode

Inverter air conditioners adjust capacity according to changes in the air conditioning load and the difference between the indoor temperature and set temperature is small, giving higher comfort levels than with non-inverter air conditioners.

Intelligent Eye

Detect human movement in a room by using infrared sensor to prevent energy wastage.

Automatic fan speed

The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature.

Fan only

The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature.

Automatic operation

This function automatically selects cooling or heating operation mode based on the room temperature at start-up.

Outdoor Unit Quiet Operation

Outdoor unit operating sound pressure levels are decreased from the rated operation sound using the wireless remote controller.

Indoor Unit Quiet Operation

The 2.5 kW class models provide a low sound level of just 25 dB (A) when Quiet (SL) is selected.
Selecting Indoor unit quiet operation, which decreases the sound pressure level by 3 to 4 dB (A) below low setting will help you to sleep comfortably at night.

Programme Dry Function

Indoor unit operating sound pressure levels are decreased from the Low setting fan speed using the wireless remote controller.

Air-Purifying Filter

This filter removes impurities such as dust, pollen and cigarette smoke as well as bacteria and viruses from the air.

Wipe-Clean Flat Panel

The flat panel design can be cleaned with only the single pass of a cloth across its smooth surface. The flat panel can also be easily removed for more thorough cleaning.

Titanium apatite deodorising filter

While the filter’s micron-level fibres trap dust, titanium apatite effectively adsorbs odours and allergens, as well as deodorises odours. This filter delivers consistent performance for approximately three years if it is washed with water once every six months.

Coanda Effect

Coanda masks winds upward, winds are cooled near the ceiling, and then covered underneath, creating a comfortable environment and reducing cold winds blowing into the body.

Inverter Powerful Operation

Inverter air conditioners operate at maximum capacity as soon as they start up. This burst of increased power allows them to reach the set temperature more quickly.

Econo Mode

After the indoor temperature approaches the set temperature, inverter control adjusts to low capacity operation to maintain this temperature, making inverter models more energy saving than non-inverter models.

Daikin Mobile Controller (optional adaptor)

The Daikin mobile controller application lets you manage Daikin inverter air conditioners from anywhere, helping to maintain a comfortable home environment while saving. Controlling function can be done in-home as well as out of home.

Indoor Unit On/Off Switch

The unit can be conveniently started manually

 

Wireless Remote Controller

The wireless remote controller has a range of up to 7 meters for main operations

Timer operation

Automatically switching air conditioner on/off at night or in the morning

Night set mode

For your pleasant sleep. This fuction adjust temperature to prevent excessive cooling or heating

 

Auto-Restart

Automatically operates airconditioner & returns to the recent setting after power failure is restore.

 

Self diagnosis

Multi function codes are shown on the wireless remote controller for fast and easy maintenance.

 

Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins

Coating heat exchanger A thin acrylic resin layered to enhance the fin’s resistance to acid rain & salt corrosion.

 

Specifications

Model Name Indoor Unit FTHF25RAVMV FTHF35RAVMV FTHF50RVMV FTHF60RVMV FTHF71RVMV
Outdoor Unit RHF25RAVMV RHF35RAVMV RHF50RVMV RHF60RVMV RHF71RVMV
Capacity Cooling Rated
(Min.-Max.)
kW 2.5 (1.0-3.4) 3.5 (1.2-3.8) 5.0 (1.6-6.0) 6.0 (1.6-6.7) 7.1 (2.1-7.5)
Heating 2.5 (1.0-3.4) 3.5 (1.2-3.8) 5.0 (1.6-6.0) 6.0 (1.6-6.7) 7.1 (2.1-7.5)
Cooling Rated
(Min.-Max.)
Btu/h 8,500 (3,400-11,600) 11,900 (4,100-13,000) 17,700 (5,500-20,500) 20,500 (5,500-22,900) 24,200 (7,200-25,600)
Heating 8,500 (3,400-11,600) 11,900 (4,100-13,000) 17,700 (5,500-20,500) 20,500 (5,500-22,900) 24,200 (7,200-25,600)
Power Consumption Cooling Rated
(Min.-Max.)
W 610 (200-1,170) 980 (200-1,440) 1,315 (350-1,740) 1,740 (360-1,950) 2,370 (700-2,500)
Heating 610 (210-1,170) 980 (230-1,120) 1,315 (350-1,740) 1,740 (360-1,950) 2,370 (700-2,500)
CSPF [tooltip] 6.00 5.30 6.30 5.70 5.50
Energy Efficiency Level [tooltip] Cooling ★★★★★ ★★★★★ ★★★★★ ★★★★★ ★★★★★
Heating ★★★★★ ★★★★★ ★★★★★ ★★★★★ ★★★★★
Indoor Unit FTHF25RAVMV FTHF35RAVMV FTHF50RVMV FTHF60RVMV FTHF71RVMV
Sound Pressure Level
(H/L/SL)
Cooling dB(A) 40/35/29/25 41/36/30/26 44/40/35/28 44/41/36/30 46/42/37/31
Heating 40/35/30/27 41/36/31/28 44/40/35/32 44/40/35/32 46/42/37/34
Dimensions (HxWxD) mm 283 x 770 x 226 295 x 990 x 266
Outdoor Unit RHF25RAVMV RHF35RAVMV RHF50RVMV RHF60RVMV RHF71RVMV
Sound Pressure Level Cooling dB(A) 48/44 48/45 47/44 47/44 51/45
Heating 48/44 48/45 48/45 49/45 52/46
Dimensions (HxWxD) mm 550 x 658 x 275 595 x 845 x 300
Operation range Cooling oCDB 10 - 46
Heating oCWB 2 - 20
Note: The above values are based on operation with a 220 V, 50 Hz power supply.

Measurement conditions

  • Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m.
  • Heating capacity is based on: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; piping length 7.5 m.
  • Sound pressure levels are based on the temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
  • CSPF is based on TCVN 7830: 2015 conditions.
Catalog Catalog Where to buyWhere to buy
Back to top